15
Specication
PHYSICAL
ENVIRONMENTAL LIMITS
APPROVALS
POWER REQUIREMENTS
Housing
• IP40 aluminum metal case
Dimensions
• 145.3mm (H) x 45mm (W) x 108.7mm (D)
Operating Temperature
• -10
℃
to 60
℃
(14
˚
F to 140
˚
F)
Weight
• 300g
Installation
• Industrial DIN-Rail and wall mounting
Storage Temperature
• -40
℃
to 85
℃
(-40
℉
to 185
℉
)
Ambient Relative Humidity
• 5% to 95% (non-condensing)
Input Voltage
• 1 set, 12 to 48 VDC terminal block input
Input Current
• Max. 0.18A
Overload Current Protection
• Present, max. input current 3A
Reverse Polarity Protection
• Present
Buffer Time
• Min. 13ms at 24VDC
Product Port Combination Interface
Model Name
Operating
Temperature
Combo Port
10/100/1000Base-T and
100/1000Base-SFP
10/100/1000
Base-T
10/100
Base-T(X)
DI
DO
(Relay)
Power
Input
DVS-G008I00A -10
℃
to 60
℃
--- 8 --- --- --- 1
DVS-G005I00A -10
℃
to 60
℃
--- 5 --- --- --- 1
Ordering Information
Safety
• UL 508, EN 60950-1, IEC 61131-2
EMI
• FCC 47 CFR Part 15 Subpart B Class A,
IEC 61000-6-4, EN 55022
EMS (IEC 61000-6-2)
• IEC 61000-4-2 level 3, IEC 61000-4-3 level 3,
IEC 61000-4-4 level 4, IEC 61000-4-5 level 2,
IEC 61000-4-6 level 2, IEC 61000-4-8 level 4,
IEC 61000-4-29
Freefall:
• IEC 60068-2-32
Vibration:
• IEC 60068-2-6
Hi-Pot:
• 1.5KV
Environmental Type Tests
Cold Temperature:
• IEC 60068-2-1
Dry Heat:
• IEC 60068-2-2
Humidity:
• IEC 60068-2-30
Shock:
• IEC 60255-21-2
Optional Products
DVP/CliQ/PMC Series: 12/24 VDC Industrial Power Supply
Industry
Ethernet Switches
IEEE 802.11 WLAN Ethernet Gateways
Commenti su questo manuale