Delta Electronics DTB4896RR Manuale Utente Pagina 3

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 19
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 2
108
C2000 Series
3 phase
040 055 075 110 150 185 220 300 370 450 550 750 900 1100 1320 1600 1850 2200 2800 3150 3550
A A B B B C C C D D D D E E F F G G H H H
4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 185 220 280 315 355
8.4 10 14 19 25 30 36 48 58 73 88 120 143 175 207 247 295 367 438 491 544
10.5 12 18 24 32 38 45 60 73 91 110 150 180 220 260 310 370 460 550 616 683
normal duty: 0.1 – 600 Hz; heavy duty: 0.00 – 300 Hz
2 – 15kHz 2 – 10kHz 2 – 9kHz
7.6 9.6 14 18 24 29 34 45 55 69 84 114 136 167 197 235 280 348 417 466 517
9.5 11 17 23 30 36 43 57 69 86 105 143 171 209 247 295 352 437 523 585 649
2 – 15kHz 2 – 10kHz 2 – 9kHz
14.5 16 19 25 33 38 45 60 70 96 108 149 159 197 228 285 361 380 469 527 594
15.5 17 20 26 35 40 47 63 74 101 114 157 167 207 240 300 380 400 494 555 625
3-phase AC 380V – 480V (-15% – +10%), 50/60Hz
323 – 528 Vac
47 – 63 Hz
fan cooling
built-in optional
optional built-in
1: V/F, 2: SVC, 3: VF+PG, 4: FOC+PG
up to 150% or above at 0.5Hz; up to 150% at 0Hz for 1 minute
4-point adjustable V/f curve and square curve
max. 200% torque current
normal duty: 0.01 – 600.00Hz; heavy duty: 0.00 – 300.00Hz
digital command: ± 0.01%, -10°C – +40°C, analogue command: ± 0.1%, 25 ±10°C
digital command: 0.1Hz, analogue command: 0.03/60Hz (±11 bits)
normal duty: 120%; heavy duty: 150% of rated output current for 1 min.
-10 – +10V , 0 – +10V, 4-20mA, pulse input
0.00 – 600.00 / 0.0 – 6000.0 seconds
torque control, speed/torque control switching, feed forward control, zero-servo control, momentary power loss ride through, speed search, over-torque detection, torque limit, 16-step speed
(including master speed), accel/decel time switch, S-curve accel/decel, 3 wire sequence, auto-tuning (rotational, stationary), dwell, slip compensation, torque compensation, skip frequency,
frequency upper/lower limit settings, DC injection braking at start/stop, high slip braking, PID control (with sleep function), energy saving control, MODBUS communication (RS-485 RJ45)
max. 115.2kbps, fault restart and parameter copy.
ON/OFF switch PWM control
electronic thermal relay protection
thermal current forces 240% of the over-current protection, current clamp: normal duty 170 – 175%; heavy duty: 180 – 185%
drive will stop when DC-BUS voltage exceeds 820V
built-in temperature sensor
stall prevention during acceleration, deceleration and running independently
parameter setting can be up to 20 seconds
ground current protection level is 50% of rated current of the AC motor drive
-
250 320 400 550 590 940 1000 1435
130 190 250 330 370 420 550 700
170 190 210 275 300 300 397 398
EtherNet/IP - MODBUS TCP -PROFIBUS-DP - DeviceNet - CANopen communication cards - Relay card (6 relays)
- I/O extension card (4 digital inputs and 2 digital outputs) - input extension card (6 inputs) various PG (encoder) feedback cards
- digital keypad with multi-function keys, warning indicators and fault code display IP56 panel mounting.
AC motor drives
Vedere la pagina 2
1 2 3 4 5 6 7 8 ... 18 19

Commenti su questo manuale

Nessun commento