English- 1Preface Thank you for choosing DELTA’s high-performance VFD-E Series. The VFD-E Series is manufactured with high-quality components and mat
English- 10Terminal Symbol Terminal Function Factory Settings (NPN mode) ON: Connect to DCM MO1 Multi-function Output 1 (Photocoupler) Maximum 48VDC,
English- 11Pr. Explanation Settings Factory SettingNOTE00.01 Rated Current Display of the AC motor drive Read-only #.# 00.02 Parameter Reset 0: P
English- 12Pr. Explanation Settings Factory SettingNOTE00.12 50Hz Base Voltage Selection 0: 230V/400V 1: 220V/380V 0 Group 1 Basic Parameters 01.0
English- 13Pr. Explanation Settings Factory SettingNOTE01.21 Delay Time at 10Hz for Simple Position0.00 to 600.00 sec 0.00 01.22 Delay Time at 20H
English- 14Pr. Explanation Settings Factory SettingNOTE01.40 Mid-Point Frequency (Fmid) (Motor 3) 0.10 to 600.0 Hz 1.50 115V/230V series: 0.1V to
English- 15Pr. Explanation Settings Factory SettingNOTE02.05 Line Start Lockout 0: Disable. Operation status is not changed even if operation comm
English- 16Pr. Explanation Settings Factory SettingNOTE02.14 Initial Frequency Selection (for keypad & RS485/USB) 0: by Current Freq Command 1:
English- 17Pr. Explanation Settings Factory SettingNOTE03.05 Terminal Count Value 0 to 9999 0 03.06 Preliminary Count Value 0 to 9999 0 03.07
English- 18Pr. Explanation Settings Factory SettingNOTE04.03 Keypad Potentiometer Negative Bias, Reverse Motion Enable/Disable 0: No negative bias
English- 19Pr. Explanation Settings Factory SettingNOTE Bit11:MI12 0:N.O., 1:N.C. P.S.:MI1 to MI3 will be invalid when it is 3-wire control. 04.
English- 2Specifications Voltage Class 115V Class Model Number VFD-XXXE 002 004 007 Max. Applicable Motor Output (kW) 0.2 0.4 0.75 Max. Applic
English- 20Pr. Explanation Settings Factory SettingNOTE Bit8: MI9 Status Bit9: MI10 Status Bit10: MI11 Status Bit11: MI12 Status 04.27 Internal/
English- 21Pr. Explanation Settings Factory SettingNOTE06.03 Over-Torque Detection Mode (OL2) 0: Disabled 1: Enabled during constant speed operatio
English- 22Pr. Explanation Settings Factory SettingNOTE 06.11 Fourth Most Recent Fault Record 06.12 Fifth Most Recent Fault Record 27: DC
English- 23Pr. Explanation Settings Factory SettingNOTE07.15 Motor PTC Overheat Warning Level 0.1~10.0V 1.2 07.16 Motor PTC Overheat Reset Delta L
English- 24Pr. Explanation Settings Factory SettingNOTE07.36 Motor Line-to-line Resistance R1 (Motor 3) 0~65535 mΩ 0 07.37 Motor Rated Slip (Motor
English- 25Pr. Explanation Settings Factory SettingNOTE08.17 Auto Energy Saving0: Disable 1: Enable 0 08.18 AVR Function 0: AVR function enable 1
English- 26Pr. Explanation Settings Factory SettingNOTEa09.08 Transmission Speedfor USB Card 0: Baud rate 4800 bps 1: Baud rate 9600 bps 2: Baud ra
English- 27Pr. Explanation Settings Factory SettingNOTE10.00 PID Set Point Selection 0: Disable PID operation 1: Keypad (based on Pr.02.00) 2: 0 t
English- 28Pr. Explanation Settings Factory SettingNOTE11.00 Multi-function Output Terminal MO2/RA2 0 11.01 Multi-function Output Terminal MO3/RA3
English- 29Pr. Explanation Settings Factory SettingNOTE23: Quick Stop (Only for VFD*E*C models)24: Download/execute/monitor PLC Program (PLC2) (NOT
English- 3General Specifications Control System SPWM(Sinusoidal Pulse Width Modulation) control (V/f or sensorless vector control) Frequency Setting
English- 30Pr. Explanation Settings Factory SettingNOTE12.18 Max. ACI3 Input Current 0.0 to 20.0mA 20.0 12.19 Max. ACI3 Scale Percentage 0.0 to
English- 31Fault Name Fault Descriptions Corrective Actions Low voltage The AC motor drive detects that the DC bus voltage has fallen below its min
English- 32Fault Name Fault Descriptions Corrective Actions Overload 2 Motor overload. 1. Reduce the motor load. 2. Adjust the over-torque detect
English- 33Fault Name Fault Descriptions Corrective Actions Auto accel/decel failure 1. Check if the motor is suitable for operation by AC motor d
English- 34Fault Name Fault Descriptions Corrective Actions CANopen SYNC Time out (Only for VFDxxxExxC) Check if CANopen synchronous message is abn
English- 35NOTE Frame A (A1): VFD002E11A/21A/23A, VFD004E11A/21A/23A/43A, VFD007E21A/23A/43A, VFD015E23A/43A, VFD002E11C/21C/23C, VFD004E11C/21C/23C/
English- 36Frame C HH1W1WS1S2DD1D2 Unit: mm [inch] Frame W W1 H H1 D D1 D2 S1 S2 C1 130.0 [5.12] 116.0 [4.57] 260.0[10.24]246.5[9.70]169.2[
English- 4Storage/ Transportation Temperature -20 oC to 60 oC Ambient Humidity Below 90% RH (non-condensing) Vibration 9.80665m/s2 (1G) less than 20
English- 5+-Please use brake unit and/or brake resistor depending on type and applicationBra ke un it (optional)BUEBRbrake resistor(opti onal)Figu
English- 6C. PNP mode without external power D. PNP mode with external power Sw1FactorysettingNPNPNP Sw1FactorysettingNPNPNP 24Vdc-+ Figure 5 RJ-4
English- 7Operation Steps of the Digital Keypad To s hif t d a taSetting PLC ModeSetting ModeSetting direction(When operation source is digital keyp
English- 8Power Terminals and Control Terminals Frame AFrame BFrame C Frame Power Terminals Torque Wire Wire Type R/L1, S/L2, T/L3 A U/T1, V/T2,
English- 9The Specification for the Control Terminals RS-485 port 10VMI1 MI2 MI3 MI4 MI5 MI6DCM24VDCMACMAVI ACIAFM MCM MO1RARB