Chapter 9 Writing Data in MySQL
Revision March, 2014 9-19
9.1.2 Create HMI Project File
Start DOPSoft software program and click File > New or click New icon to create a new
project. Then, click Element > Input > Numeric Entry to create two numeric entry
elements ($3 and $6) on the screen. In this case, 10 inches color B10E615 type DOP
series HMI is used.
Use Screen Cycle Macro and enter the following commands in macro command window.
Click Options > Communication Setting > Ethernet > LocalHost, set HMI IP Address
and check the Application(eRemote / eServer) function Enable. Then, press OK button to
finish the settings.