Chapter 4 Excel Sampling Setting
Revision March, 2014 4-19
ODBC
ODBC logging also provide user could select usage node or not. And the default value is
according to each ODBC data base setting to data table for allow nullsand default value”.
Allow nulls have three kinds of state:
a. If set allow nulls for not null and uncheck usage then logging data, eServer will display
error message and stop logging.
b. If set allow nulls for null and does not set default value, eServer will fill with empty to
replace data.