2 Functions of Devices in DVP-PLC
DVP-PLC Application Manual
2-118
11. Operation Procedure of EASY EASY PLC LINK
Set up the Slave ID# to be read
Set up the number of data in Slave to be read
Set up the Slave ID# to be written
Set up the number of data in Slave to be written
(If there is no set value, use the previous set value or the default
value.)
Disable
Enable
Set M1354
Reset M1354
Enable auto/maual
mode of EASY PLC
LINK
Set M1351
Set M1350
Disable 32 slaves linkage and up to
100 data for exchange.
(Reset M1353)
1. Enable 32 slaves linkage and up to
100 data for exchange (set M1353).
2. Set up the register D for storing the
read data.
3. Set up the register D for storing the
written data.
Disable
Enable
Enable manual mode
Enable auto mode
Communicating
by Modbus 0X17
Start to execute EASY PLC LINK
Enable 32 slaves
linkage and up to
100 data for exchange
Set M1352
Set times of communication
(D1431)